Everywhere in the advanced dental clinics show kind consideration for the agreeable atmosphere for patient. For example, gentle appearance and interior design of the clinic, cure space with full protection of privacy, creation of relaxing atmosphere by aromatherapy, …
The same consideration is also requested to X-ray unit which is essential for dental diagnostic.
Cypher E is a solution of the new generation digital panoramic X-ray unit attaching the importance to the provision of agreeable atmosphere for both patient and clinic.
The same consideration is also requested to X-ray unit which is essential for dental diagnostic.
Cypher E is a solution of the new generation digital panoramic X-ray unit attaching the importance to the provision of agreeable atmosphere for both patient and clinic.

Cypher E has the basic performances to provide clear image and excellent operability as well as “the function gentle to human and environment”. For example, when you align the positioning beams to a patient, Cypher E moves to the position automatically with the beams. Cypher E is capable of smooth exposure without compelling a patient to take unnatural posture. After exposure, X-ray image of the patient is displayed on a PC monitor at the side of the chair in real time. Further, the versatile image processing function of the software provides the diagnosis information necessary for dental care, supports the clinic to provide advanced dental care and correct orientation of treatment, and supports the clinic to enhance the quality of informed consent.

The first the eye-catching of a patient who enters to the X-ray room is X-ray unit.
Dressed in pearly white appearance, Cypher E creates luxury, fashionable and clean atmosphere for patient. Also its round form realizes to give mild impression.
Gentleness and comfortableness are expressed in the design of Cypher E.
Dressed in pearly white appearance, Cypher E creates luxury, fashionable and clean atmosphere for patient. Also its round form realizes to give mild impression.
Gentleness and comfortableness are expressed in the design of Cypher E.

Cypher E is equipped with functions gentle to patients and staff in the clinic.
Setting of Exposure Factors
Exposure factors can be set only by selecting icons of exposure mode and patient size that are displayed on a monitor.

Panoramic image (adult)

Panoramic image (child)

TMJ 4 section views (lateral view)

Automatic positioning with laser beam
Cypher E moves automatically interlocking with 3 bright laser beams for positioning median, eye-ear plane and anterior teeth.
This enables smooth work from positioning to exposure and reduces the load of operator and patient.
This enables smooth work from positioning to exposure and reduces the load of operator and patient.


Realized speedy operation
Integrated operation panel and illustrated easy-to-know buttons are adopted.
Integrated operation panel and illustrated easy-to-know buttons are adopted.

Swing type mirror for easy positioning
Both the patient and the operator can see the positioning state. This enables correct and quick positioning.
Both the patient and the operator can see the positioning state. This enables correct and quick positioning.

Reduction of X-ray dosage
Super high frequency inverter DC high tension generator to minimize the generation of soft X-ray enables to take high image quality X-ray exposure with low dosage. High sensitivity digital COMS sensor realized the exposure with dosage less than half of the conventional exposure using X-ray film.
Super high frequency inverter DC high tension generator to minimize the generation of soft X-ray enables to take high image quality X-ray exposure with low dosage. High sensitivity digital COMS sensor realized the exposure with dosage less than half of the conventional exposure using X-ray film.

Easy conditional setting for exposure
You can set the exposure condition easily. The only thing you have to do is to select the exposure mode and patient size displayed on the PC monitor. Wide range combination of tube voltage 60 to 80 kV (1 kV step) and tube current 2 to 8 mA (1 mA step) provides the optimum exposure condition.
You can set the exposure condition easily. The only thing you have to do is to select the exposure mode and patient size displayed on the PC monitor. Wide range combination of tube voltage 60 to 80 kV (1 kV step) and tube current 2 to 8 mA (1 mA step) provides the optimum exposure condition.
Technical Specification | ||
Generic name | Digital panoramic X-ray diagnostic unit | |
---|---|---|
Product name | Digital Panoramic X-ray equipment | |
Type | Cypher E | |
Source voltage | 100/110/120/200/220/230/240V 50/60Hz, 1![]() | |
Power requirement | 1.5 kVA | |
High voltage generator | Inverter type | |
Tube voltage | 60 to 80 kV (1 kV step) | |
Tube current | 2 to 8 mA (1 mA step) | |
Exposure | Manual exposure | |
X-ray tube | D-052SB | |
Focal spot | 0.5 mm | |
Total filtration | 2.5 mm Al (min) | |
Exposure mode | Panoramic : Adult/Child TMJ 4 section views (lateral view) | |
Exposure time | Panoramic : 10 sec TMJ 4 section views (lateral view) : 2.5 sec (×4) | |
Image magnification | Panoramic : 1.2 to 1.3 TMJ 4 section views (lateral view) : 1.2 | |
Image sensor | CMOS sensor | |
Positioning beam | 3 beams (median, ear-eye plane, anterior teeth) | |
Dimensions | W : 906 × D : 1,126 × H : 2,200 (mm) | |
Weight | Approx. 165 kg |
Operating Environment | |
Temperature | 5 to 35 °C |
---|---|
Humidity | 30 to 85 % |
Atmospheric pressure | 700 to 1,060 hPa |
Cypher E Dimensions

*Elevation with 855 mm stroke of the unit enables the operator to radiograph a patient flexibly. Cypher E with optional L-shape base is applicable to a patient on a wheel chair.
PT.MEGA MEDIKA JAYA
Operational Office :
Jl. Tanjung Barat Selatan No. 115 RT 01 RW02
Account : 14100.10000.11.30.0
Kel. Lenteng Agung, Kec. Jagakarsa
JAKARTA SELATAN
12610 INDONESIA
Phone : 62-21-78830461
Fax :
62-21-78830461
Mobile : 085770226999, 081213786999
E-mail : alkes.megamedika@gmail.com
BANK : BRI Kantor Kas Tanjung Barat
Account :
14100.10000.11.30.0
Tidak ada komentar:
Posting Komentar